Brocade M6505 is on NO_Sigdet state
I cannot map server to any port in both AG mode and native mode because port status show No_SigDet. How can I solve it. I already install server module and driver of fabric card on OS. Port of server...
View ArticleHow to connect two FC-Switches
Hi I want to connect two Brocade FC-Switches. When I do that I see on Switch1: >switchshow Area: 3 Port: 3 Media: id Speed: N2 State: Online E-Port segmented,(disabled E_Port) Switch2:...
View ArticleConfigdownload fails with SNMP issue
We are completely replacing a FC5022 switch in an IBM Flex Chassis with the same make/model switch. We backed up the config prior to replacement and are now having issues when trying to do a...
View ArticlePropagate IP switch address through the fabric
Hi guys, Do you know how could I hurry up the propagation of a new IP address (modified from an old one) of a switch through the fabric it is part of? Thanks, Mugur
View ArticleBrocade 300 FOS7.1 ipv6 gateway configuration
Hello, its first time i try to create ipv6 ip addresses. I found the procedure via CLI and web tools how to create ipv6 management address+subnetmask but i have not found a way to configure ipv6...
View ArticlePort random timeouts/resets on ISL over DWDM
I have two DCX directors connection through the Cisco DWDM 15454SDH over 4Gb and 2Gb ports, two different providers distances 15 and 20 km.DWDM is the card I think TDM with ports with speeds 1,2,4 Gb....
View Article4100 Switch Help Needed - Newbie!
Hi all, I have just got my first ever FC switch (4100) and I am connecting to a few Xserves and 1 x Xraid. I haven't used a FC switch before so really need some pointers in the basic setup of the...
View Articlefabric on model 300
Hi, i have problem with two switches model 300. I need this switches connect to fabric. Domain IDs are 1 for SW001 and 2 for SW002 My licenses on both swithes: SW001:admin> licenseshow...
View ArticleWeb Tools will not load, but EZ Switch Manager does
I have two new 300 switches. Came with FOS v6.4.3c. I racked and configured IP (et al). I can SSH to the switches. I am running Java 1.6.0_16 per FOS v6.4.3c release notes. I can launch EZ Switch...
View ArticleThe factory has collapsed after the Switch, which had previously been turned...
The factory consists of five switch modules (version 6.2.2.d at all, 200e 2040 model) 4020 was some time off, at which time the factory was changed, introducing new zone and alies. After switching on...
View ArticleHow to recover admin or root password.
Hello, I have sigle fabric swith brocade 300, OS version 6.3.1B, i need to know what is the process for recover root or admin password
View Articlehow to switch to withdraw from the factory?
Good afternoon. how to switch to withdraw from the factory. (200E, 4020)?
View ArticleFCIP Tunnel up no connection: NPVID -> E -> EX ->VEX ---VEX
I have a POC I am trying to setup and am not seeing the issue in what I have. The connection is a bit "odd" I have a pair of Brocade 8Gb 24 port switches at each "site" (physically linked with 1Gb CAT...
View ArticleSevere latency bottleneck detected on ISL / Trunk port
Hello, could anyone give me a hint how to troubleshoot error "Severe latency bottleneck detected" on ISL/trunk port? What can cause this problem and how a root cause can be found? We received this...
View ArticleBrocade 8000 enable IDLE timeout in cmsh mode
In FOS Native mode, we know the command "timeout" to set IDLE mode = timevalue or 0 to disable login timeout. try to find for the same or equivalent command when the switch is set in "cmsh" mode, but...
View ArticleUnable to zone in IM3
Hi fellow SAN Admins. I have a fabric which runs in IM3 mode. It used to be a mix of McDATA ED-140, I10K, DCX and 5300 switches. This weekend, I had the last hosts moved to the DCX/5300 switches, and I...
View ArticlePorts info list of full DCX
Hi, I need a ports info list preferably in XLS or TXT or CSV format, can you send me me or point me for a full size 8 blade x 48 port DCX. I need director port numberblade numberblade port numberSCSI...
View ArticleHigh Values for Time BB Credit Zero - Is this a problem and how is it fixed?
I have an issue with a networker media host connected to tapes only sometimes losing sight of the networker controller hosts and it tape drives. I have noticed that the media host has high values for...
View ArticleBrocade 48000 EOL and Blades (fc4-32 and fc8-48)
Greetings, I'm aware of the EOL notice governing the Brocade 48K. My question is what is the EOL for blades themselves? Specifically, fc4-32 and fc8-48)? Thanks in advance!
View ArticleChange IP for Brocase 200E FC Switch
Hi We are planning to change the IPs for our EMC SAN and for the FC switches. Shall anyone help us to change the IPs, also will it affect any configured zones or production servers and SANs connected...
View Article