C3 Frames Discarded at ISL Ports

$
0
0
Hello everybody,   we have 4 DCX Directors in a Two Fabric topology and two datacenters   Between the datacenters the directors are connectet with longwave ISLs. In the last time appear on some ISL ports "C3 Frames Discarded" errors.  

Why some wwns not visible in the Access Gateway are visible in the switch Fabric

$
0
0
Hello everybody,   I will appreciate any input that help me to understand what is happening in the following issue :   I have an IBM  Blade Center working with NPIV connected to a Brocade switch configured as Access Gateway and the N

cannot load RBACMatrix

$
0
0
I have a Brocade DS5000 getting this error. My client java version is 1.5.0_20   DS5000 Current HTTP configuration       javaplugin.version = 1,5,0,6       javaplugin.homeURL =

How do you connect to fiber switches?

$
0
0
I have a new IBM Blade Center H with 2 internal fiber switch modules. 6 external ports / 14 internal ports. I have an existing DELL / EMC SAN running on 2 McData DS4700M 32 port switchs. I'd like to connect the Blade switches to the existing switches

Severe latency bottleneck detected on ISL / Trunk port

$
0
0
Hello,   could anyone give me a hint how to troubleshoot error "Severe latency bottleneck detected" on ISL/trunk port? What can cause this problem and how a root cause can be found?   We received this alert on trunk created from two 8Gbit

Webtools Java Error

$
0
0
Hi experts   I am unable to open the Webtools GUI for Brocade switch. It gives a java error message below. Help please.   Java version installed in mgmt server : java 6 update 35 (64-bit)

Portcfgfillword - Mode 3 for 8GB HBA

$
0
0
I just upgraded one of my switch with v7.1.1. I noticed that "Portcfgfillword" command is not supported anymore. I used to run this command before I upgraded to make sure the mode was set to 3 when I used 8GB HBA cards. I could not find any resource and

8GBps speed

$
0
0
I have one issue in one of installation, we provide 1 storage IBM DS3512 (Dual Controller) and IBM Bladecenter H with 2 x Brocade 20 Port 8GB SAN Switch (44X1920), we attached the SAN switch directly to storage but when we configure a port in Brocade SAN

SupportSave failing

$
0
0
On one of our DCX running OS v6.2.0e I am attempting to run SupportSave but keep getting the following error:   supportSave is already running from another connection, please retry later. SupportSave failed   I tried waiting overnight but

Reset counters displayed by command Porterrshow??

$
0
0
How do you reset the counters displayed when the "porterrshow" command is issued??  We are trying to debug a problem and showing counters from power-up confuses the issue. Thanks Much In Advance Ron NOTE: This content was migrated by Brocade from

What is Proc_rqrd?

$
0
0
I have a couple switches (300e) ISL'd and in portshow it has a high proc_rqrd count. All other counters are clean. Can anyone share some light on this counter?

Interop M5424 & 4424 (DELL Blade) with Nexus 5000

$
0
0
Is it supported to configure DELL blade switch model M5424 and 4424 into "access gateway" mode to connect with a Nexus 5598 (in normal FC mode)? Thanks, Dominique

Port random timeouts/resets on ISL over DWDM

$
0
0
I have two DCX directors connection through the Cisco DWDM 15454SDH over 4Gb and 2Gb ports, two different providers distances 15 and 20 km.DWDM is the card I think TDM with ports with speeds 1,2,4 Gb. On DCX is using Exchange-based policy routing. The

Forcing the domain ID on a switch

$
0
0
Hello,      I want/need the domain ID of a swith to be set to an arbitrary value.      I've tried on a "standalone" switch running with DID 1 up to now. It sort of made me think it accepted the change, but on the web

Chassis is not ready for management now. Please try after some time.

$
0
0
I am having this issue with a 48000 director with FW 6.2.0g after adding it to the Fabric. There are 30 switches in the fabric and all are accessible via telnet. Webtools works on all but the 48000 which says "Chassis is not ready for management now.

How to recover admin or root password.

$
0
0
Hello,   I have sigle fabric swith brocade 300, OS version 6.3.1B, i need to know what is the process for recover root or admin password

FOS 6.4.3 to 7.0.0c upgrade failed

$
0
0
Checking system settings for firmwaredownload...   The following item(s) need to be addressed before downloading the specified firmware: Upgrade to 7.0 is not allowed because the threshold configuration changed alarm is set for class

DCX poweroff procedure

$
0
0
Hello,   I am looking to find an official poweroff procedure for a DCX4.   I am not able to get the documentation from the mybrocade.com   Regards,   Philippe

What is MS platform service and what is the use of it?

$
0
0
Hello All, I have a question on MS platform service, not able to understand what is it and what is it's need and when it is used in Fabric. I got  it in FOS admin guide in Fiber channel services. Thanks in advance.

FCping output.

$
0
0
Hallo if I do a "fcping --number 200 10:00:00:00:c9:5c:7f:06" i get the following result(excerpt):   received reply from 10:00:00:00:c9:5c:7f:06: 12 bytes time:197 usec received reply from 10:00:00:00:c9:5c:7f:06: 12 bytes time:9580 usec received