Quantcast
Channel: Brocade Communities : Popular Discussions - Fibre Channel (SAN)
Viewing all 722 articles
Browse latest View live

supportftp - has Brocade kept this command (6.4.2a) up to date ?

$
0
0
After using DCFM/BNA for many years I am working at a site with no such tool and I need to use the cli commands to do things like configupload & supportsave. I am using FOS 6.4.2a issue could be present on many other versions.   I'm not

Link Timeout

$
0
0
Dear All   10.66.12.173S0,P-1(23): Link Timeout on internal port  ftx=-1367794193 tov=2000 (>1000) vc_no=1 crd(s)lost=5 complete_loss:1.  From the above msg i would unserstand that there is reset on VC 1, but is it due to BB credits

DS-5100 Command Line Interface Commands

$
0
0
Hello,   I am looking for a document that lists the command line commands for the DS5100.   I would like to issue a command to get a listing of servers and what storage processor FC ports they are connected to.   Any help would be

Brocade 5340 with Port to Non-port side airflow?

$
0
0
Are there a Brocade 5340 with Port to Non-port side airflow?

SAN Switch FabOS Upgrade Guide

$
0
0
I have not done many Brocade firmware upgrades before. Is there an upgrade guide or matrix available to follow? Thanks

Where do I download the latest FOS (V7.1?)

$
0
0
This is for DCX8150-4. Please email your answer or questions to yhuang@itg.com.   Thanks!

SAN hiccup when apply zones or adding devices

$
0
0
Hi, I have 2x 48000 running firmware version 5.2.1b. Attached has Hitachi 9960, HP EVA 8000 and MSA 1500, VMware esx 3.01 servers, win 2003, Sun servers. Recently when adding a msa 1500, a esx server, applying zones to switch will cause SAN hiccup, i.e.

DCX-4S-B merge via ICL

$
0
0
Hi Experts,   We have the  existing DCX-4S-B in our environment Site 1 Virtual Fabric info in the DCX Base Fabric on the Core Blades Virtual Fabric 1 for user connectivity Virtual Fabric 2 for connectivity to Site 2   Site 2

IBM 3534 Factory Reset

$
0
0
Hoping someone can help.   I've purchased a IBM 3534-F08 off ebay and of course cant access the CLI as i don't have the admin password as it have been changed from the factory default.   I have scoured the net to look for instructions on a

How to reset / recover lost password from a IBM 2498-B24 SAN switch running Fabric OS?

$
0
0
Hello Experts,   I have two IBM 2498-B24 SAN switches running Brocade Fabric OS with Linux kernel 2.6. These two switches were brought quite a time ago and NO ONE knows the passwords of them.   However, now it is required two create new SAN

SupportSave failing

$
0
0
On one of our DCX running OS v6.2.0e I am attempting to run SupportSave but keep getting the following error:   supportSave is already running from another connection, please retry later. SupportSave failed   I tried waiting overnight but

Brocade 4100 Firmware download link

$
0
0
Hello,   I am trying to find a link where I can download firmware v6.1.0c for a Brocade 4100 switch, model SLKWRM0000410? I have tried in vain to get it through Level 1 Brocade Technical Support who bounced me to Oracle who bounced me back to

Discover WWNs on NPIV

$
0
0
Hi   I have some ports on SAN768b switch with NPIV config. When I run switchshow, the only information that I can get is: 131   13   03fc80   idN4   Online  FC  F-Port  1 N Port + 4 NPIV

ONLINE SAN MERGE

$
0
0
hello all I have to merge two fabrics online, with a minimum of outage. One of the scenario is : - all zones, alias are not duplicated in the two active configs - all DIDs are unique - fabric parameters have same values on all the 2 fabrics

SAN80B integrated routing and licensing ..............help needed

$
0
0
Hello Techie's I am setting up new fabric consisting of SAN80B's located across 2 Site that are separated by distance of  more then 300 miles ,setup plan is like:

What is Proc_rqrd?

$
0
0
I have a couple switches (300e) ISL'd and in portshow it has a high proc_rqrd count. All other counters are clean. Can anyone share some light on this counter?

Network Advisor shows two switches in DOWN state - yet they're up

$
0
0
A couple weeks ago we had a power down at our data center.  When power was restored and we brought the SAN infrastructure up we experienced zero issues.  However, when I looked at our SAN Directors via Network Advisor they both have a Red

Reset counters displayed by command Porterrshow??

$
0
0
How do you reset the counters displayed when the "porterrshow" command is issued??  We are trying to debug a problem and showing counters from power-up confuses the issue. Thanks Much In Advance Ron NOTE: This content was migrated by Brocade from

Interop mode for Cisco MDS connected to Brocade DCX and EMC ED-140M

$
0
0
Hi,   We have SAN network consisted from Brocade DCX configured with "Interop mode 0 (interop mode off)" and EMC ED-140M configured with "Open Fabric 1.0".   Is there possibiltiy to connect Cisco based SAN switches (MDS series) to existing

300 Switch Licensing Issue after Upgrade to 7.0.1

$
0
0
We have multiple Dell/EMC CX4 SANs all with Brocade 300 FC Switches.  We hired a reputable well known company to support us with the upgrade of the SANs and FC Switches to the latest versions. They collected logs analyzed them, planned the upgrades,
Viewing all 722 articles
Browse latest View live