Hello i'm newbie in Brocade. We have 2 brocades SilkWorm 200e, on of them was never configured and i successfully setup IP address for it using EZswitchsetup, after that get access to webtools and everything ok. Second one brocade was configured (i can't
↧
Unable to access brocade with no one service (telnet, ssh, http etc) only using console, plz help?
↧
how to remove switch from sec policy ?
Hello Gurus I am facing some issue while restoring the configuration of one production (IBM B16-2005) switch into backup SAN switch (IBM 2498-B24). When I give the configdownload command, Its gives me following message Can only
↧
↧
Forcing the domain ID on a switch
Hello, I want/need the domain ID of a swith to be set to an arbitrary value. I've tried on a "standalone" switch running with DID 1 up to now. It sort of made me think it accepted the change, but on the web
↧
Shutdown a switch properly
Few of our switches doesn't Power I/O buttron on the rear/back side of the switch. What is the right process for to power off these kind of switches (don't want pull-out the power cable) ?
↧
How to setup a brocade 300 switch
Hi, We are going to configure brocade 300 switch in our environmental . We are having VMware servers and we didn't have director fabric . we have to connect from hba to brocade 300 and from there to Dell storage . So my question is that we have
↧
↧
Need 6510 Front-end port to ASIC mappings
Need 6510 front-end port to ASIC mapping. Also need to verify 6510 uses two Condor-2 ASICS.
↧
Invalid Transmitted Word count > 750000 after 12 hours. What could be wrong?
Hi all, I've recently installed a large Sun StorageTek SL3000 tape library in one of our data centers. My existing fabric consists of 4 * Brocade Silkworm 200E's running FabOS 6.2.0c. The two new switches, for the SL3000 are Brocade Silkworm
↧
SFPs compatible with CWDM?
Hi, I am in the process of installing a point to point Dark Fibre between two Data Centres for DR purposes. The sites are approx 8km apart, the cable run is estimated at approx 20km but I am being conservative and saying 30km. I intend to
↧
Link Timeout
Dear All 10.66.12.173S0,P-1(23): Link Timeout on internal port ftx=-1367794193 tov=2000 (>1000) vc_no=1 crd(s)lost=5 complete_loss:1. From the above msg i would unserstand that there is reset on VC 1, but is it due to BB credits
↧
↧
Active directory integration
Hi, I try to integrate a 5300 into an existing active directory. First, I created a OU called SAN. Second, I added a group called "SANAdmins" including me as user. Next, I configed the switch with aaconfig to recognize
↧
Basic Switch Replacement Questions
I'm in the midst of updating our SAN to replace really old switches and get the FOS levels up to date. We have 2 redundant fabrics. Output from 'fabricshow" below (without actual names & IP addresses) Switch ID Worldwide
↧
Cannot Open Switch Explorer
Hello, I have two Brocade Fiber Switch Modules in an IBM BladeCenter H. I was having trouble with one of them so I reset it back to factory defaults. Once reset I can no longer connect to it through Switch Explorer. I get the
↧
How do you connect to fiber switches?
I have a new IBM Blade Center H with 2 internal fiber switch modules. 6 external ports / 14 internal ports. I have an existing DELL / EMC SAN running on 2 McData DS4700M 32 port switchs. I'd like to connect the Blade switches to the existing switches
↧
↧
FCIP tunnel Transfer Rate
Hi, We have an FCIP set up of 7500E from DC to DR which is running on a 1Gbps link. The commit rate of FCIP Tunnel has been set to 512000Mbps(.512Gbps) in both 7500E . As per my understanding the max. data can be transfer through this link
↧
password recovery
Hello, Please appriciate, if anyone can help me to recover the password for 3534-f08 and 2005-H16 san switches or share any documentation that can help. Thanks
↧
How to connect two FC-Switches
Hi I want to connect two Brocade FC-Switches. When I do that I see on Switch1: >switchshow Area: 3 Port: 3 Media: id Speed: N2 State: Online E-Port segmented,(disabled E_Port) Switch2: >switchshow Area: 4 Port: 4
↧
Brocade 4424 (for Dell Blade) Fabric OS
Hi, currently we have a Fabric OS 5.3.0. Is there a 6.x release for this switch and where can I download it? Thanks, Jargo
↧
↧
Difference between Access Gateway mode and switch mode
We have a HP C7000 blade enclosure which needs to be connected to SAN environment (through DCX). The interconnect module in C7000 is 8GB brocade switch (Switch type 72.3) 1) Now i have two option for interconnect module to be set,
↧
Brocade 200E initial configuration
All, We have a new 200E switch thats being installed by Vendor, but I dont have any configuration available on that particular switch. I tried to take the console of the switch using a serial cable and also with a Cross Cable.
↧
Brocade 300-FOS update question
Hi all, I'm a new member here and I have a quick question on updating the FOS on Brocade 300. I am currently running two Brocade 300s (8Gig FC) in a production environment. The current FOS on them is v6.2.1b I plan on updating both of them
↧